Method and sources: profiles, assumptions and what we leave out

Updated 16 Oct 2026 · KilowattTally

The calculators on this site give estimates, not measurements. We have not measured batteries, storage units or heat pumps ourselves. This page says where each figure comes from, which choices we made and what is left out.

The load profile

We use the standard load profile for households, H25, from BDEW, the German energy industry association [1]. It gives the consumption for every quarter-hour [1] over twelve months and three types of day (weekday, Saturday, Sunday and public holiday), for a consumption of 1,000,000 kWh in a year [2]. It was derived from the data of 62 grid operators for 2018 and 2019 and already contains a small effect of photovoltaic self-consumption [2]. We transform it as follows:

A standard profile is an average of many houses: yours may use more in the evening, less at midday, or have a heat pump and an electric car that the profile does not contain.

The PVGIS weather year

Production comes from PVGIS, the tool of the European Commission’s Joint Research Centre [4], with the data used under its conditions [5]. We downloaded the hourly series from 2005 to 2023 for Kassel, in the centre of Germany, for 1 kWp with system losses of 14%: modules facing south tilted at 35° and, for east-west, half the modules facing east and half facing west tilted at 15°. We use a real year, not an average day: a real year also contains the cloudy weeks in which the battery does not fill up, which an average day hides. The year is 2005, the one with production closest to the median of the 19 years: 981 kWh/kWp facing south and 811 kWh/kWp east-west. The calculator keeps the shape of that year and rescales it to the yield per kWp you enter.

The battery

Every hour, solar energy goes to the house first; the surplus charges the battery up to its usable capacity and the rest is fed into the grid; when the sun is not enough, the battery covers consumption as long as it has energy. Assumptions:

Where the curve flattens. For every capacity from 0 kWh upwards, in steps of 1 kWh, we calculate how many points of self-sufficiency the last kWh adds. We show the last capacity at which the gain is still at least 2 points per kWh and the last at which it is at least 1. The thresholds are our own choice for reading the curve, and we state them next to the result.

The heat pump

The house’s useful heat is the gas consumed times the boiler efficiency; the heat pump has to deliver the same heat, with a single annual performance factor (JAZ) for the whole year. The comparison uses the prices you enter and, if you enter them, the standing charges. As a guide to the JAZ we cite Fraunhofer ISE’s measurements in existing houses [7]. The values in the example are the BDEW averages for 2026: 37.0 ct/kWh for household electricity [8] and 11.93 ct/kWh for gas in single-family houses [9]. In the battery calculator, the example uses a feed-in payment of 7.70 ct/kWh, the rate for systems up to 10 kW commissioned between August and December 2026 [10].

The dynamic tariff

For prices we use the day-ahead price for the Germany-Luxembourg zone for every hour of 2025, published by the Bundesnetzagentur on SMARD [15], under a CC BY 4.0 licence with the attribution “Bundesnetzagentur | SMARD.de” [16]. Since 1 October 2025 the exchange has set a price for every quarter-hour [18]: for those hours we use the average of the four quarter-hours. The price of each hour is the exchange price with 19% VAT, plus the fixed part per kWh you enter.

The H25 profile is the same as for the battery, but on the 2025 calendar and in German local time, the time of the prices. For the heat pump we use the 2025 hourly temperatures from the DWD station at Schauenburg, near Kassel [19], and count heating degree hours: 20 °C minus the outdoor temperature, in the hours below 15 °C. This is DWD’s degree-day rule [20], applied hour by hour. When consumption is shifted, the heat pump uses the cheapest hours of the same day, without exceeding its highest power of the year; the car uses those of its charging window; the battery charges in the cheap hours, knowing the prices of the whole year in advance. That is why the result with shifting is an upper limit.

Balcony solar with storage

We use the same hourly engine as for the battery, with three differences. The inverter does not give the house more than the power you choose, at most 800 VA for a plug-in device [37]. The storage sits before the inverter, so it also charges with production above the limit. It returns 82.5% of the energy it takes in, the value used in HTW Berlin’s simulator, which like us does not count standby losses [45]. The simulator derives it for an AC-coupled storage unit with a battery inverter of 0.5 W per Wh [45]; we place the storage before the inverter and do not limit its power. For modules on the railing we added the 2005 PVGIS series for Kassel with vertical modules facing south, east and west [4].

Where the curve flattens. In steps of 0.5 kWh we show the last capacity at which each extra kWh takes at least 100 kWh a year off the grid and the last at which it takes at least 50. These are our own thresholds, in kWh rather than points of self-sufficiency, because with a small system the points depend mostly on how much the house consumes.

What we do not calculate, on purpose

Advertising

Below some calculators there are links to partner services for the chosen country: comparisons of electricity tariffs for heat pumps, quote requests to installers, dynamic tariff suppliers and manufacturers of balcony storage units. They are labelled as advertising, appear below the result and do not change it: the calculation is the same with or without those links, and there is no partner form on our pages.

Sources

  1. Repräsentative Profile BDEW H25, G25, L25, P25, S25 (Veröffentlichung) · BDEW Bundesverband der Energie- und Wasserwirtschaft, retrieved 13 Oct 2026
  2. Hinweise zu den aktualisierten Standardlastprofilen Strom (Anwendungshilfe, 17. März 2025) · BDEW Bundesverband der Energie- und Wasserwirtschaft, retrieved 13 Oct 2026
  3. Anwendung der Repräsentativen VDEW-Lastprofile step-by-step · VDEW (oggi BDEW), retrieved 13 Oct 2026
  4. PVGIS 5.3, serie orarie (seriescalc), banca dati PVGIS-SARAH3 · Commissione europea, Joint Research Centre (JRC), retrieved 13 Oct 2026
  5. PVGIS data download (condizioni d'uso e citazione) · Commissione europea, Joint Research Centre (JRC), retrieved 13 Oct 2026
  6. Stromspeicher-Inspektion 2026 · HTW Berlin e aquu, retrieved 13 Oct 2026
  7. Wärmepumpen heizen auch im Altbau klimafreundlich: Forschungsprojekt abgeschlossen (comunicato stampa, 3 novembre 2025) · Fraunhofer ISE, retrieved 13 Oct 2026
  8. BDEW-Strompreisanalyse Herbst 2026 · BDEW Bundesverband der Energie- und Wasserwirtschaft, retrieved 13 Oct 2026
  9. BDEW-Gaspreisanalyse August 2026 · BDEW Bundesverband der Energie- und Wasserwirtschaft, retrieved 13 Oct 2026
  10. EEG-Förderung und -Fördersätze · Bundesnetzagentur, retrieved 13 Oct 2026
  11. Marktdaten: Großhandelspreise, Day-Ahead, Deutschland/Luxemburg (dati orari 2025) · Bundesnetzagentur, SMARD.de, retrieved 14 Oct 2026
  12. Datennutzung (condizioni d'uso dei dati) · Bundesnetzagentur, SMARD.de, retrieved 14 Oct 2026
  13. Viertelstundenscharfe Großhandelspreise verfügbar (10 ottobre 2025) · Bundesnetzagentur, SMARD.de, retrieved 14 Oct 2026
  14. Stündliche Lufttemperatur, Station 15207 Schauenburg-Elgershausen (historical, 2013–2025) · Deutscher Wetterdienst, Climate Data Center, retrieved 14 Oct 2026
  15. Datensatzbeschreibung: Aktuelle tägliche Gradtage nach VDI 3807 für Deutschland · Deutscher Wetterdienst, Climate Data Center, retrieved 14 Oct 2026
  16. Erneuerbare-Energien-Gesetz (EEG 2023), § 8 Anschluss · Bundesministerium der Justiz, gesetze-im-internet.de, retrieved 14 Oct 2026
  17. Dokumentation Stecker-Solar-Simulator, versione 3.0 (maggio 2024) · HTW Berlin, Forschungsgruppe Solarspeichersysteme, retrieved 14 Oct 2026